Filter Results By:

Products

Applications

Manufacturers

Ground Resistance

Evaluation of the conductance of earth grounding.

See Also: Ground Resistance Clamps, Ground Resistance Testers, Surface Resistivity


Showing results: 121 - 135 of 141 items found.

  • Solid State Relays for Switching Heavy Loads with Physically Small 6-pin DIP Package

    Part No. ZD20CD - Teledyne Defense Electronics Relays & Coax Switch

    Series ZD20CD solid-state relays use an advanced design capable of switching heavy loads in a physically small 6-pin DIP package These relays have a power FET output that ensures low ON resistance and low leakage current. Optical isolation ensures complete protection of signal lines, power and ground bus and control circuits from switching noise and EMI.MSL 6ZD20CD 1A, 60Vdc Load; 8-20mAdc Control; through hole mountedSZD20CD 1A, 60Vdc Load; 8-20mAdc Control; surface mounted

  • Hipot Testers

    Hypot® Series - Associated Research

    The Hypot Series sets the standard for safety and efficiency in production line Hipot Testing. Whether your application requires AC Withstand tests, DC Withstand tests, or Insulation Resistance tests, The Hypot Series provides innovations that will allow you to begin achieving best practices for safety and efficiency without the need for an expensive automated test system or connection to a PC. You can even connect the Hypot Series with the HYAMP Series to form a seamless safety compliance system for Hipot and Ground Bond Testing.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    783864-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    785189-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    785186-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    779592-01 - NI

    4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    783864-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • Solid State Relays for Switching Heavy Loads with Physically Small 6-pin DIP Package

    Part No. ZD20CF - Teledyne Defense Electronics Relays & Coax Switch

    ​Series ZD20CF solid-state relays use an advanced design capable of switching heavy loads in a physically small 6-pin DIP package These relays have a power FET output that ensures low ON resistance and low leakage current. Optical isolation ensures complete protection of signal lines, power and ground bus and control circuits from switching noise and EMI.MSL 6Available options include:ZD20CF 2A, 60Vdc Load; 8-20mAdc Control; through hole mountedSZD20CF 2A, 60Vdc Load; 8-20mAdc Control; surface mounted

  • Solid State Relays for Switching Heavy Loads with Physically Small 6-pin DIP Package

    Part No. ZD24CC - Teledyne Defense Electronics Relays & Coax Switch

    Series ZD24CC solid-state relays use an advanced design capable of switching heavy loads in a physically small 6-pin DIP package These relays have a power FET output that ensures low ON resistance and low leakage current. Optical isolation ensures complete protection of signal lines, power and ground bus and control circuits from switching noise and EMI.MSL 6Available options include:ZD24CC 0.5A, 80Vdc Load; 8-20mAdc Control; through hole mountedSZD24CC 0.5A, 80Vdc Load; 8-20mAdc Control; surface mounted

  • POWER PROBE 4

    PP401 - Matco Tools

    *Electronic circuit and component tester that supplies battery ground and power along with 8 diagnostic testing modes to provide automotive technicians with detailed information on the circuits and signals being tested*Diagnostic Modes include: AC/DC Voltmeter, Ohmmeter, Frequency, Pulse width (Positive and Negative) Fuel Injector Tester, PCM/ECM Driver Tester and PPECT3000 Signal tracer*Tests for AC/DC voltage in 100ms and 50s resolutions, AC volts RMS and volts peak-to-peak, measure resistance, frequency and pulse width (negative and positive)

  • AC Ground Bond Tester

    446 - SCI

    Our 446 model is a 4-in-1 tester with AC Hipot, DC Hipot, Insulation Resistance, and Ground Bond capabilities. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application. The 446 is equipped with multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Add to user safety by equipping your tester with Personal Protective Equipment (PPE) via the built-in safety interlock.

  • Digital Ior Leakage Current Clamp Tester

    MCL-400IR+ - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).

  • The Mag Lead

    136 - Electronic Specialties Inc.

    *Mag Lead features a magnetic disconnect near the test probe end. *Just disconnect the test probe and you can “stick” to any metallic ground or test point. *Quit fumbling with alligator clips that fall off - Mag Lead’s powerfull magnet will hold tight! *This is a time saving tool - if you don’t have to walk to your tool box to retrieve your alligator clips, even on just half the occasions, then you’ve saved time. *Very helpful for automotive reference points and troubleshooting. *Can eliminate the need to hold probes while checking or monitoring a signal. *Two high power, low resistance magnets hold the probe to the lead. *Fits almost all Digital Multimeters and can be used with hand-held scopes too. *Get the Mag Lead, it stays put and won’t fall off, like alligator clips do!

Get Help